                 Changes in version 0.1.6 (2026-07-30)                  

    o   plotPK no longer loses series when a study has more than 18
	subjects or treatments. The colour vector had a fixed length of
	18, and indexing past its end gave NA, which draws nothing at
	all, so every subject after the 18th was silently missing from
	the pooled profiles. Colours are now generated for any number
	of series, and plotting symbols vary as well.

    o   plotPK draws the subject legend in a panel of its own, sizing
	the text and the number of columns to fit. Previously the
	legend was placed inside the plot region with a fixed colour
	vector, so with many subjects it overlapped the curves, ran off
	the figure, and mislabelled series through silent recycling.

    o   plotPK lays treatment panels out in a grid of at most four
	columns. The former single row of nTRT panels asked for a right
	margin of 2.5*nTRT lines and a raster 700*nTRT pixels wide,
	which failed with “figure margins too large” from about eight
	treatments onward.

    o   plotPK drops non-finite values before computing axis ranges. A
	single NA concentration used to abort the whole function with
	“need finite 'ylim' values”.

    o   plotPK closes every graphics device it opens, even when a panel
	fails. A failed call used to leave the device open, so the
	caller's next plot was written into the half-finished file.

    o   plotPK sanitizes the file-name stem taken from the concData
	argument, and accepts an explicit name argument. Calling it
	with an expression such as d[d$ID != "S001", ] used to fail
	with “cannot open file”.

    o   plotPK prints the per-bin counts as one line; the whole vector
	used to be drawn on top of itself. Its mean profile also sizes
	the y axis to the error bars instead of clipping them, warns
	about subjects left out of the mean, and no longer requires
	binr.

    o   Semi-logarithmic axes in plotPK, pdfNCA and rtfNCA are aligned
	to whole decades enclosing the data. The previous trunc()-based
	tick positions could all fall outside ylim, leaving the y axis
	blank.

    o   plotFit plots only positive concentrations instead of
	substituting 0.1 for zeros, includes the fitted intercept in
	the y range, and reports a clear error for an unknown ID.

    o   conv.pp works with a single-column result; it used to fail with
	“subscript out of bounds”.

    o   Subset compares whole columns instead of one cell at a time,
	and rejects an unknown key with a clear message.

    o   foreNCA checks for the columns it needs and reports an empty
	selection instead of failing inside forestplot.

    o   NCA0 uses a single concentration unit and warns when the PC
	records disagree. readEX no longer requires an EXENDTC column.

    o   plotPK returns the paths it wrote, invisibly.

    o   rNCA now runs at all. Since the first release it has passed a
	one-row data.frame to NCA0, which indexes its EX argument by
	name; the result was a one-column data.frame where a string was
	expected, and every call made the way the documentation
	prescribes - with ex and pc from loadEXPC() - died inside
	NonCompart::Unit() with “non-character argument”. Passing a
	matrix instead failed differently, because subsetting a matrix
	drops a single matching row to a vector. Both input shapes are
	now accepted and normalized once on entry.

    o   rNCA's six near-duplicate code paths (single versus multiple
	dosing, interior versus last dosing interval, one versus
	several analytes) are one loop over dosing intervals. A single
	dose is simply a subject whose only interval is also its last.

    o   rNCA sorts EX and PC records by date and time, so the result no
	longer depends on the row order of the input. Previously
	unique() preserved file order, so EX rows supplied in another
	order - which combXPT can produce, since it binds folders in
	directory order - silently merged two dosing intervals into one
	and dropped the other, and unsorted PC rows either produced a
	scrambled profile or failed inside NonCompart.

    o   rNCA ends each dosing interval at the subject's next dose of
	any treatment. In a crossover trial analysed one treatment at a
	time, the first period used to run open-ended and absorb the
	second period's samples, overstating AUClast about threefold
	and taking Cmax from the wrong period.

    o   rNCA binds result rows by name. rbind matches by position and
	takes its column names from the first row, so a cohort mixing
	administration methods - whose parameter sets differ in length
	- wrote later rows' values under the wrong headers, reporting
	for instance a volume of distribution as a clearance, with only
	a recycling warning.

    o   rNCA finds the pre-dose sample as the last record in the day
	before the dose rather than by matching calendar dates. The old
	rule made the result depend on the wall-clock time of dosing: a
	dose shortly after midnight could never recover a trough drawn
	the previous evening. The lookback is bounded in real time
	because NCA0 places a pre-dose record at time zero, so an
	unbounded search would report a sample from the previous period
	as this dose's initial concentration.

    o   rNCA closes a dosing interval only at a real dose of the study
	being analysed. A placebo or zero dose delivers no drug and no
	longer truncates an interval, and a record that merely shares a
	subject identifier with another study no longer does either.

    o   rNCA treats a blank EXROUTE as extravascular, as NCA0 always
	has, so a cohort mixing intravenous with blank-route records is
	refused rather than silently reported with two different models
	side by side. A blank PCSPEC likewise now means plasma, as an
	absent PCSPEC column already did.

    o   rNCA orders duplicate sampling and dosing times
	deterministically and reports them, so a repeated PCDTC or
	EXSTDTC can no longer make the result depend on the row order
	of the input. Negative concentrations are also reported.

    o   rNCA resolves study, trt, id and analyte to the spellings found
	in the data, so every selector matches case-insensitively end
	to end. id=c("SUBJ-01","subj-02") used to return only the first
	subject, silently.

    o   rNCA no longer drops the last sample of every interior dosing
	interval when a PCTPTNUM column is present but blank, which the
	old unguarded string comparison did silently.

    o   rNCA matches analyte names case-insensitively throughout, and
	labels the output PCTESTCD from the data rather than from the
	caller's spelling. analyte="druga" against data holding "DRUGA"
	used to select nothing, and case variants of one code were
	analysed as two half profiles.

    o   rNCA tolerates a non-numeric PCSTRESN, warning and ignoring it,
	instead of aborting the whole run with “missing value where
	TRUE/FALSE needed”. It also accepts character(0) and NULL
	selections, checks for the SDTM columns it needs, supplies the
	same defaults as readEX/readPC for the optional ones, warns
	when records are dropped for an unusable date/time or when a
	dosed subject has no plasma record, and checks routes after
	selection rather than before.

    o   rNCA and NCA0 estimate the terminal slope of an infusion from
	post-infusion samples only, controlled by the new
	excludeInfusion argument and ON BY DEFAULT. The automatic
	search constrains itself to samples after the maximum
	concentration, which says nothing about an infusion, so a
	sample drawn while drug was still going in could win on
	adjusted R-squared and be reported as terminal elimination; a
	terminal phase does not exist while drug is still going in. The
	same maximum-adjusted-R-squared criterion still selects the
	window, now among the post-infusion samples. Only lambda z and
	what derives from it (half-life, AUCIFO, AUCPEO, Vz) are
	affected; Cmax and AUClast cannot change. Too few post-infusion
	samples produces a warning naming the profile and falls back to
	the unrestricted search, so no profile is lost silently. Pass
	excludeInfusion=FALSE to reproduce results from an earlier
	version. The restriction applies to the SDTM entry points,
	which know the dosing record; sNCA and tblNCA remain faithful
	wrappers around NonCompart.

    o   sNCA gained UsePoints, passed through to NonCompart, which
	fixes the terminal-slope window explicitly instead of searching
	for it. The UsedPoints attribute now survives the returnNA=TRUE
	padding.

    o   NCA0 decides the administration method from EXROUTE first.
	Testing the recorded duration first classified any
	extravascular record carrying an EXENDTC - routine in real EX
	domains - as an infusion, so an oral dose was reported with
	VZO/CLO/VSS in place of VZFO/CLFO/MRTEV.

                        Changes in version 0.1.5                        

    o   Core noncompartmental computation is now delegated to the
	NonCompart package, so pkr and NonCompart share one maintained
	engine and always give identical results. This fixes, among
	others, the handling of NA concentrations in sNCA and the
	column mis-alignment of tblNCA/NCA with heterogeneous subjects.

    o   NCA() with a treatment (trt) argument no longer errors on an
	undefined dose object.

    o   readPC now defaults optional PCSPEC/PCLLOQ/PCSTAT/PCORRES
	columns correctly and recognizes more BLQ codes.

    o   combXPT no longer requires the first folder to contain the
	domain file.

    o   plotPK now writes to the outdir argument, and its mean
	annotations use the actual means.

    o   txtNCA reports the correct administration route and infusion
	length.

    o   plotFit draws the semi-log axis and terminal-slope line
	correctly.

    o   foreign, binr, forestplot, and rtf moved from Depends to
	Imports; NonCompart added to Imports.

                        Changes in version 0.1.4                        

    o   Rare cases raising NaN in BestSlope are handled.

                 Changes in version 0.1.3 (2022-06-11)                  

    o   Column order bug with bolus infusion fixed.

                 Changes in version 0.1.2 (2018-06-04)                  

    o   Deprecated option in Sys.timezone() is removed.

                 Changes in version 0.1.1 (2017-07-10)                  

    o   pkr A bug in C0 calcuation of IV bolus case was fixed.

                 Changes in version 0.1.0 (2017-03-14)                  

    o   First version